Skip to main content

J-Series J5T-IP

Ethernet Thermostat with Integrated BAS Protocols

  • Commercial Touchscreen Ethernet Thermostat
  • Standard (Gas/Electric) up to 2H/2C
  • Heat Pump up to 3H/2C
  • Humidity Sensing & Dehumidification Control
  • 2 x 10K Thermistor Inputs
  • 1 x Digital Input
  • NetX Internal Expansion Port
  • 7 Day Programmable + 80 Calendar Events
  • Onboard Data Logging
  • BACnet/IP, Modbus TCP/IP, SNMPv2 Embedded
    Features

    Energy Savings

    • Efficient Equipment Restart™ randomizes equipment starts to minimize multiple units turning on simultaneously when there are multiple NetX thermostats at the location
    • Random Restart on power-up staggers restart of the HVAC system after a power outage to minimize peak in-rush current
    • Adaptive Recovery for Schedules allows system to achieve desired setpoint at the beginning of the schedule

    Monitoring

    • Two 10K thermistor inputs for remote room temperature and pipe temperature sensing for 2-pipe auto-changeover applications
    • One Digital Input for general alerting or wired NetX Occupancy Sensors
    • NetX Expansion Port for CO2, NLC Lighting, and other future accessories
    • On-board Data Logging with Sub-Metering Support
    • Connectivity
    • NetX-Cloud™ Internet-Based Cloud Service
    • Local Network & Port Forwarded Access
    • DirectConnect™ Integrated Web Server
    • Integrated NetX™ API, Supports 3rd Party Apps
    • BACnet/IP and Modbus TCP/IP over Ethernet (use either or both)
    • SNMPv2

    Facility Management

    • 4 independent schedules per day

    • 80 Additional Calendar Events (40 Special and 40 Calendar)

    • Commercial Lockout with Programmable Temporary Override Time and Temp Adjustment

    • Min/Max Heating and Cooling Restrictions

    • Email & Text Message Alerting for up to 4 Recipients

    • Alerts include High/Low Temps for Indoor, Outdoor, Inefficient Equipment Operation, Change Filter Notifications, and more

    General

    • Sleek Black Touchscreen Display with White Icons, Black or White Case

    • Modes: Heat, Cool, Automatic Changeover

    • Integrated Humidity Sensing and Dehumidification Control

    • Fan Selector for Independent Fan Control

    • Programmable Recirculation Fan

    • Integrated Weather with Current Conditions and 7-Day Forecasts

    • Embedded Web Server with responsive design allowing access from any device with a browser

    Rated Voltage:
    20-30 VAC, 24 VAC nominal

    Rated A.C. / D.C. Current:
    0.05 - 0.75A AC, 0.0 - 0.75A DC continuous, per output, surges to 3 Amps maximum

    Temperature Control Range:
    Heating: 38˚F to 88°F (4˚C to 31°C) in 1° steps; Cooling: 60˚F to 108°F (16˚C to 42°C) in 1° steps

    Thermostat Sensing Range:
    32˚F to 118°F (0˚C to 48°C); Control Accuracy:
    ±1°F @ 68°F (±0.5°C @ 20°C)

    Minimum Deadband:
    2°F (1°C)

    Dimensions:
    5.1”H x 3.25”W x 1.08”D (130mm x 82.5mm x 27.4mm)

    Mounting:
    Single Gang Vertical Mount, Standard 3 9/32” Screw Hole Spacing

    Equipment Terminations:
    R - 24V Switching Voltage 
    G - Fan 
    Y1–Compressor 1
    Y2 – Compressor 2
    W1 - Heat1 or Aux/Emer Heat
    O/W2 - Rev. Valve Cooling or Heat2
    B – Rev. Valve in or Heating

    Power Terminations:
    R - 24V Switching Voltage (from HVAC equipment)
    24V - Separate Power (24 VAC/DC) 
             requires jumper removal
    C - Power Return (from HVAC equipment)

    Universal Input Termination: 
    Selectable 24V or 0-10VDC Input

    10K Thermistor Terminations: 
    T1, T2, GND (both 10K-Type II and 10K-Type III support)

    Ethernet:
    10/100Mbps, 802.3, Auto Negotiation, Auto-MDIX

    Internal Expansion Port:
    NetX Expansion Port for NetX CO2 Sensor, NLC Lighting Control, NetX future accessories

    The J5T-IP-B (black case) and J5T-IP-W (white case) are Ethernet touchscreen thermostats with two 10K thermistor inputs and one digital input, designed for new or replacement commercial and residential applications. Use the J5T-IP for either conventional or heat pump applications (Gas/Elect 2H/2C, HP 3H/2C) with rooftop, Split, FCU, and other equipment types. The J5T-IP also has a revolutionary NetX Expansion Port for the NetX CO2 sensor, NLC Lighting Control, or other future accessories.  The powerful processor allows near-effortless setup of your daily schedules (4 events per day) and up to 80 Calendar Events (40 Special and 40 Calendar). The unique scheduling structure also supports the powerful features of adjustable temporary override times and temperature ranges, occupied and unoccupied events, touchscreen lockout, and many more features. In addition to the powerful NetX ecosystem, the J5T-IP also includes both Modbus TCP/IP and BACnet/IP over Ethernet, directly on the thermostat.

    The J5T-IP is designed to operate with our NetX-Cloud™ Online Management software and/or behind your firewall using DirectConnect™ to the embedded web server. With all functions stored in the thermostat, the J5T-IP will continue to operate even during network outages, allowing you to maintain your energy savings. For ultimate control over energy usage, the J5T-IP offers a digital lockout that can permit limited temperature overrides based on your requirements. The on-board data collection allows for historical review, sub-metering, and run-time reporting.

    Sensor